Sean W. asked

🔌  Appliance

My Whirlpool refrigerator WSR57R18DM02 is not cooling, even after changing the capacitor, relay, and overload on the compressor. The compressor runs, but the box does not cool, and the low side pressure fluctuates between 5 psi and 18 psi. The condenser fan also slows down and speeds up. What could be the issue, and what steps should I take to resolve it?

August 26th, 2023

Shannon S. answered

The primary issue seems to be a refrigerant leak, indicated by the hot compressor. This is a common ...